ScienceSkills
Chemistry & Drug Discovery

nmrglue

Processes calibrated one-dimensional complex NMR free-induction decays with nmrglue into phased spectra, peak candidates, and signed integration regions. Use for raw 1D NMR processing, ppm-axis verification, apodization, Fourier transformation, manual phasing, baseline correction, or reproducible spectral integration.

View source files ↗Set up this skill ↓

Use this skill in your project

This is a readable source snapshot, not a hosted execution service. Review the upstream files and your agent’s loading rules before installation.

  1. Get the repository and inspect SKILL.md and its referenced files.
  2. Copy the complete skill folder into your agent’s documented skill directory. The directory depends on your agent.
  3. Install the dependencies specified by the skill. API access, data and compute may carry separate costs.
  4. Start with a small input and verify the output before running a full analysis.
Repository download and setup guide →

A prompt to adapt

I want to use the nmrglue skill for [research task]. Read its SKILL.md and referenced files first. Ask about my input data, expected output and environment. Identify dependencies and credentials before proposing steps. Start with a small example and state how I can check the result.

License (source snapshot)MIT
Compatibility (source snapshot)Requires Python 3.12+, nmrglue, NumPy 2+, and SciPy. Installation needs network access; processing is local and needs no credentials.
Skill version (source snapshot)1.1
Last reviewed (source snapshot)2026-10-01
Author (source snapshot)K-Dense Inc.
Source transparency
Documentation recovered from the site snapshot dated 17 October 2026. Upstream version fields below are source claims, not a new verification by ScienceSkills. No execution benchmark is claimed.

Skill documentation

nmrglue: calibrated 1D FID processing

When to use

Use for a uniformly sampled complex 1D FID whose acquisition parameters and complex frequency convention are available. The helper produces a descending ppm spectrum, positive peak candidates, signed region integrals, and a reproducible processing report. It does not identify compounds or assign resonances.

The executable accepts a NumPy .npz containing exactly one complex fid array or a canonical 1D complex time-domain NMRPipe file. NMRPipe reading is tested with a synthetic write/read round trip, known-spectrum recovery, and a small upstream NMRPipe-generated binary fixture. Experimental Bruker, Varian, and JEOL imports are not verified by this suite. For those formats, first inspect the relevant nmrglue reader and acquisition metadata. Opening a converted file does not validate the original acquisition decoding. Read references/acquisition-and-validation.md for conversion boundaries, axis calibration, and quantitative limits.

Workflow

  1. Preserve the raw FID. Establish spectral width in Hz, positive observation frequency in MHz, carrier in ppm, observed nucleus, and the sign convention from the acquisition or a known reference. Determine whether digital-filter/group-delay removal has already occurred. Do not infer these from array length or typical instrument defaults.
  2. Copy assets/processing.json and replace its synthetic example values with the measured parameters and explicit processing choices. Its sign -i means a resonance at offset f = (ppm - carrier_ppm) * observation_mhz has time dependence exp(-2*pi*i*f*t). Select +i only for the opposite convention; the helper conjugates it before processing. Validate with a known reference peak.
  3. Choose nonnegative exponential line broadening (Hz), an even zero-filled size at least as large as the acquired FID, first-point scaling, and phase angles. Zero filling improves interpolation, not acquired spectral resolution. First-point scaling 0.5 is suitable for the supplied causal synthetic example; acquisition and prior preprocessing may require another value.
  4. Run the helper, inspect the real and imaginary spectra, and revise manual phase if needed. phase0_deg + phase1_deg * index / zero_fill_points is applied after FT; index zero is the high-ppm edge. There is no implicit pivot or automatic phase estimate.
  5. Only fit a linear baseline when explicitly supplied ppm regions are signal-free. Set baseline to linear and add baseline_regions_ppm containing at least two regions. Inspect residuals and broad peaks; fitting through signals biases integrals.
  6. Compare peak positions with references, inspect peak candidates for artifacts, and integrate specified regions. Report overlapped peaks as overlapped. Preserve negative areas as diagnostic evidence of phase/baseline problems instead of taking absolute values.

Execute

Tested with Python 3.12, nmrglue 0.12, NumPy 2.5.3, and SciPy 1.18.1:

uv run --no-project --python 3.12 --with nmrglue==0.12 --with numpy==2.5.3 --with scipy==1.18.1 \
  python skills/nmrglue/scripts/process_1d.py fid.npz processing.json nmr-result

Paths assume the collection root. Adjust them when installed elsewhere. The output directory must be new, so repeated processing keeps previous results reviewable.

For an existing 1D NMRPipe FID, add --input-format nmrpipe and supply its path in place of fid.npz. The helper requires the canonical FDF2 direct dimension, complex quadrature, a time-domain flag, and agreement between header and JSON spectral width, observation frequency, and carrier. JSON settings remain explicit; a mismatch fails instead of silently recalibrating. FDF2TDSIZE must equal the stored complex-point count, and FDF2CENTER / FDF2ORIG must describe a canonical centered axis. Previously zero-filled, truncated, or recentered files need a separate acquisition-aware workflow. The nucleus/complex sign and previous digital-filter corrections still need acquisition evidence. A time-domain flag alone does not establish an unprocessed FID.

This executable synthetic example matches the supplied settings, generates resonances at 3 and 7 ppm in a 1:2 amplitude ratio, and does not represent an experimental sample:

import numpy as np

t = np.arange(8192) / 4000.0
fid = sum(a * np.exp(-np.pi * 2.0 * t)
          * np.exp(-2j * np.pi * (ppm - 5.0) * 400.0 * t)
          for ppm, a in [(3.0, 1.0), (7.0, 2.0)])
np.savez("fid.npz", fid=fid)

Run it with assets/processing.json as the settings argument. The repository suite executes this signal and the CLI, checks both peak locations within 0.001 ppm, checks integral ratio and analytic area, and checks phase and baseline recovery. The NMRPipe round-trip test writes this FID using ng.pipe.create_dic/ng.pipe.write, reads it through the CLI, and verifies the recovered peaks and integral ratio. Processed frequency-domain files and conflicting calibration metadata are rejected.

The 2,176-byte upstream fixture checks complex sample order and header calibration using a file generated by NMRPipe's simTimeND / SET tools. Those native tools were not run in this review; this is fixture compatibility, not a live NMRPipe processing comparison.

Deliverables and interpretation

  • spectrum.csv: descending ppm, real signal after baseline correction, phased imaginary signal, and the fitted real baseline. Plot NMR with the high-ppm end on the left.
  • report.json: input/settings SHA-256, package versions, all settings, acquired duration, zero-filled digital spacing, positive peak candidates, and signed region areas.

Integrals use endpoint interpolation and trapezoidal integration along increasing ppm; area units are arbitrary signal times ppm, independent of display direction. Regions outside the sampled ppm axis fail rather than being silently clipped. Peak prominence is a fraction of the largest positive real intensity; it is not a noise-derived detection limit. Strong solvent signals can obscure weak candidates at the default threshold.

For quantitative NMR, additionally establish relaxation delay, pulse angle, saturation, receiver behavior, internal/external reference amount, and integration uncertainty. The helper does not calculate concentrations or correct unequal relaxation. Preserve these limits with the result rather than converting arbitrary areas to molecule counts.

Upstream contracts

The hosted latest documentation identified itself as 0.9-dev when checked; the actual 0.12 package APIs and numerical behavior were tested. Its proc_base.fft uses the negative-exponent NumPy FFT followed by fftshift; NMRPipe's FT convention corresponds to fft_positive, so do not substitute it without revisiting the FID sign and phase. See the v0.12 processing source. Multidimensional processing, nonuniform sampling, automated assignment, and experimental vendor imports remain outside this helper's validated scope.

Explore related skills

13c-metabolic-flux

Estimates intracellular metabolic fluxes from steady-state carbon-13 isotope-tracing measurements using validated atom maps, mfapy isotope simulation, constrained multistart fitting, and flux-profile diagnostics. Use for 13C-MFA, carbon tracing, mass isotopomer distributions (MDVs/MIDs), positional isotopomers, parallel tracer experiments, and determining whether labeling data constrain a pathway flux. Distinguishes measured-label inference from COBRA flux balance analysis and flags experiments requiring nonstationary MFA.

Chemistry & Drug Discovery

analytical-method-validation

Plans, executes, and documents validation, verification, and transfer of analytical procedures under the governing framework - ICH Q2(R2) and Q14, USP <1220>/<1225>/<1226>, ICH M10 bioanalytical, CLSI EP, or ISO/IEC 17025. Use for HPLC, LC-MS/MS, GC, CE, ICP-MS, dissolution, qNMR, qPCR, NIR, and ligand binding or cell-based assays whenever the question is whether a procedure is fit for its intended purpose. Triggers include "method validation", "analytical method validation", "AMV", "validation protocol", "acceptance criteria", "linearity", "reportable range", "accuracy and precision", "repeatability", "intermediate precision", "recovery", "LOD", "LOQ", "detection limit", "quantitation limit", "specificity", "robustness", "method transfer", "method comparison", "Deming", "Passing-Bablok", "Bland-Altman", "equivalence testing", "OOS investigation", "ICH Q2", "Q2(R2)", "Q14", "USP 1225", "ICH M10", "incurred sample reanalysis", "ISR", "CLSI EP", and any request to show that an assay works.

Chemistry & Drug Discovery

cantera

Runs Cantera homogeneous chemical reactors and evaluates ignition delay with mechanism provenance, conservation checks, and numerical refinement. Use for combustion kinetics, closed adiabatic ideal-gas constant-volume or constant-pressure ignition, temperature histories, or mechanism-specific ignition-delay comparisons.

Chemistry & Drug Discovery